Registration diagnosis

When a registration fails, the endpoint shows one of these diagnoses. In the panel the title names your carrier or PBX; the button runs the action.

What you see When What to do
The carrier rejects the passwordreg.auth_rejected401 or 407The password may have changed on the other side. Enter the current one in the endpoint's settings. Button: Update password
The provider rejects the registrationreg.forbidden403Some providers answer 403 to a wrong user name or password, so check those first. If they are right, the account may be closed to registration from this address or suspended: send the copied steps to your provider. Button: Copy registration steps
User not foundreg.user_not_found404The SIP user name is probably wrong. Button: Check user name
The registrar isn't answeringreg.no_response408Check the registrar, the port, the transport and any firewall. If your provider uses an allow list, it must include your static IP. Button: Check address
The registrar's name can't be resolvedreg.dns_failedThe name can't be resolvedThe registrar wasn't found in DNS. Check the spelling. Button: Check address
The other side is temporarily unavailablereg.unavailable503This usually clears on its own; you can retry now. Button: Retry
Registration failedreg.failedAny other failureThe last attempt ended with the SIP code shown. Check the endpoint's registration steps and retry. Button: Retry
Registration attempts stoppedreg.disabled3 authentication failures in a rowRelayDock stopped trying so the provider isn't sent more wrong credentials. Fix the user name or password, then retry. Button: Retry
Couldn't set up in LiveKitlivekit.provision_failedLiveKit rejected the setupThe diagnosis shows LiveKit's error code. RelayDock retries every 10 minutes; resync after fixing the cause. Button: Resync
LiveKit isn't connectedlivekit.not_connectedNo LiveKit project, or its key stopped workingCalls can't reach your agent until a LiveKit project is connected and its key works. Button: Connect LiveKit
The edge isn't in syncedge.not_syncedThe edge hasn't picked up the latest configurationRecent changes may not be live yet. This clears without action; write to support if it lasts.

Over the API, the diagnosis is diagnosis.key on GET /endpoints/{id}. A stopped registration is retried with POST /endpoints/{id}/retry-registration.

Why a call was rejected

When RelayDock rejects a call itself, the call record's reason names the cause, and the SIP response carries it in the X-RelayDock-Reason header. A failed call without a reason usually ended at the other side: the SIP code is theirs.

Reason Why What to do
source-not-allowedSIP 403 or 407 · InboundSource not allowedThe call came from an address that isn't on the endpoint, without the endpoint's digest credentials.Add the address from the call detail (source IP) to Carrier IP addresses (trunk) or Source IPs (registration), or set up digest authentication on both sides.
digest-mismatchSIP 403 · InboundDigest mismatchThe carrier authenticated with a digest user name that isn't this endpoint's.Use the same digest user name on the carrier and on the endpoint.
no-targetSIP 480 · InboundNo LiveKit targetNo LiveKit project is connected, so RelayDock has nowhere to send the call.Connect your LiveKit project; the endpoint is set up in it automatically.
private-sdpSIP 488 · InboundPrivate media addressThe endpoint is Direct only and the carrier offered a private audio address, which LiveKit can't reach.Switch the endpoint to Automatic or Always Relay.
caller-not-allowedSIP 403 · OutboundCaller not allowedThe caller number isn't one of the endpoint's outbound caller numbers.Leave sip_number empty, or add the number to the endpoint's outbound caller numbers.
invalid-numberSIP 484 · OutboundInvalid numberThe dialed number is empty or, on a trunk endpoint, not +E.164.Dial +E.164 numbers, for example +12025550123.
no-outboundSIP 403 · OutboundNo outbound targetThe trunk endpoint has no carrier SIP address for outbound calls.Turn on Outbound calls on the endpoint and enter the carrier's SIP address.
no-registrationSIP 503 · OutboundNot registeredThe registration endpoint isn't registered right now.Fix the registration first: the endpoint's diagnosis names the cause.
emergency-not-supportedSIP 403 · OutboundEmergency numberEmergency numbers such as 112, 911 or 999 can't be called through RelayDock.Don't rely on RelayDock for emergency calls.
blocked-prefixSIP 403 · OutboundBlocked destinationThe destination is on the fraud-prevention list of premium and satellite prefixes.Write to support if you need to call this destination.
daily-capSIP 403 · OutboundDaily outbound limitToday's outbound minute limit is used up. It resets at midnight UTC; inbound calls aren't affected.Write to support to raise the limit.
srtp-directSIP 488 · OutboundEncrypted audio in Direct onlyAn ElevenLabs agent called out with only encrypted audio (SRTP) on an endpoint set to Direct only. Without relaying the audio, RelayDock can't decrypt it for your carrier.Switch the endpoint to Automatic or Always Relay, or set Media Encryption to Disabled in ElevenLabs's Outbound Configuration.
plan-limitSIP 486 · BothPlan limitYour plan's concurrent call limit is reached.Wait for calls to end, or move to a plan with more concurrent calls.
cps-limitSIP 486 · BothCall rate limitToo many new calls started in the same second for your plan.Spread out the start of your calls.
billingSIP 503 · BothNo active plan or payment on holdNew calls are paused: there is no active plan, or a payment is on hold. Registrations stay up.Choose a plan under Usage and billing, or write to support about a hold.
suspendedSIP 403 · BothSuspendedThe account is suspended. Registrations stay up.Write to support.
unknown-tenantSIP 403 · BothUnknown teamRelayDock didn't find the endpoint's team.Write to support with the time of the call.
100relSIP 420 · Both100rel not supportedThe other side requires reliable provisional responses (100rel), which RelayDock doesn't support.Turn off the 100rel requirement on your carrier or PBX.
dst-forbiddenSIP 403 · BothDestination not allowedThe registrar, carrier or LiveKit address resolves to a private or reserved address.Use a host name that resolves to a public address.
dns-failedSIP 503 · BothName not resolvedThe registrar's, carrier's or LiveKit's host name couldn't be resolved.Check the spelling of the host name.
tls-mismatchSIP 502 · BothTLS certificate mismatchThe other side's TLS certificate doesn't match the host name RelayDock connected to.Use the host name the certificate is issued for, or fix the certificate.
media-limitSIP 503 · BothMedia relay fullRelayDock's media relay was at capacity.Try again; write to support if it repeats.
relay-failedSIP 500 · BothForwarding failedThe call couldn't be forwarded to the other side.Write to support with the time of the call and its Call-ID.

timeout (Timed out) is not a rejection: the call was answered and ended without a hang-up message from either side. It is billed for at most 15 minutes.

Inbound check results

What you see What to do
No call reached RelayDock Nothing arrived within the listening window. Check that your carrier routes the number to your SIP address (trunk) or to this registration, then the allowed IPs and the inbound digest password.
The carrier's IP isn't in the endpoint's allowed list Add the address the check shows to Carrier IP addresses (trunk) or Source IPs (registration).
The carrier's digest user name doesn't match the endpoint Set the same digest user name on the carrier and on the endpoint.
The carrier dialed a number the endpoint doesn't have No endpoint has the number the carrier sent. RelayDock matched it to your check by its last 9 digits. Add the number the check shows to the endpoint, as +E.164; numbers match with or without the leading +.
LiveKit didn't answer The call passed RelayDock but LiveKit refused it with the SIP code shown. Check that the LiveKit project is verified and the endpoint is set up (ready).

Test call results

What you see What to do
LiveKit couldn't start the call LiveKit refused the request before any call was placed. Check the LiveKit project page for a key or setup error.
RelayDock rejected the callThe step names the reason.
The other side rejected the call Your carrier refused the call with the SIP code shown. Check that your carrier allows calls from this account to the destination and accepts the caller number; at Telnyx, the connection needs an outbound voice profile.
The call's final report didn't arrive LiveKit saw the call answered but RelayDock's record is missing. Check Calls for the result.

LiveKit connection errors

The LiveKit project page shows these when the key check or the ownership test call fails. Over the API they are last_error_code and verification_error on GET /target, with the prefix livekit..

Code What you see What to do
livekit.invalid_credentialsLiveKit rejected the API key or secret.Create a new API key in LiveKit Cloud and update the connection.
livekit.permission_deniedThis API key can't manage SIP. Give it SIP admin rights in LiveKit.Use a key with the SIP admin grant.
livekit.unreachableLiveKit's API didn't answer. Check the API URL.The API URL starts with wss:// or https:// and is your project's URL.
livekit.sip_host_mismatchThis SIP address belongs to a different LiveKit project.Copy the SIP address from the same project as the API key (Settings → SIP in LiveKit Cloud).
livekit.probe_rejectedLiveKit didn't accept our test call.RelayDock's ownership test call was challenged and refused. Check that the key and the SIP address belong to the same project, then verify again.
livekit.probe_timeoutLiveKit's SIP address didn't answer in time.Check the SIP address and verify again.
livekit.sip_unreachableLiveKit's SIP address can't be reached.Check the SIP address, for example abc123.eu.sip.livekit.cloud.
livekit.errorLiveKit returned an error. Try again.Retry; if it repeats, check LiveKit's status.