Docs Guides

Transfers

To hand a caller over to another number, your agent asks LiveKit to send a SIP REFER to the carrier. If the carrier refuses, the agent can bridge the call instead by calling the number on the endpoint's outbound trunk.

REFER: the carrier transfers the call

With a REFER, LiveKit asks your carrier to connect the caller to the new number; the call then leaves LiveKit and RelayDock. Call transfer_sip_participant with the caller's identity and a target URI:

  • LiveKit accepts sip:, sips: or tel: targets. Write a phone number as tel:+12025550123; a bare +12025550123 is rejected with 400 invalid_argument.
  • LiveKit waits for the carrier's final answer before it returns, so allow about 45 seconds, and check the response's status: newer livekit-api versions report a failed transfer in the response instead of raising an error.
  • Your carrier must allow REFER on the connection. Telnyx does: RelayDock verified REFER with live traffic (202, then a successful NOTIFY).

Bridge: your agent calls the number

If the REFER fails, create a SIP participant for the new number in the same room, on the endpoint's outbound trunk. The caller and the new party then talk through LiveKit; stop your agent's own audio once the bridge is up. The bridge is an outbound call: the caller number rules apply, and its minutes count.

To show the caller's dialed number to the new party, pass it as sip_number. It must be one of the endpoint's outbound caller numbers; if it isn't, leave sip_number empty.

Code

This is the transfer logic of RelayDock's own test agent (livekit-agents 1.8): REFER first, bridge as the fallback.

Python
import asyncio
import logging
import re
import time
from collections.abc import Mapping

from livekit import api, rtc
from livekit.agents import JobContext

logger = logging.getLogger("transfer")
_E164 = re.compile(r"\+[1-9][0-9]{6,14}")
# livekit-protocol SIPTransferStatus.STS_TRANSFER_FAILED. Newer livekit-api versions return this
# status for a failed transfer instead of raising.
STS_TRANSFER_FAILED = 1
# LiveKit waits for the carrier's final NOTIFY (about 30 s of ringing) before it answers.
REFER_TIMEOUT = 45.0


def refer_target(number: str) -> str:
    """LiveKit accepts sip:, sips: or tel: targets; a bare +E.164 number becomes a tel: URI."""
    target = number.strip()
    return f"tel:{target}" if _E164.fullmatch(target) else target


def caller_from_called(attributes: Mapping[str, str]) -> str:
    """The number the caller dialed, as +E.164 (empty if there is none)."""
    called = (attributes.get("relaydock.called") or "").strip()
    number = called if called.startswith("+") else f"+{called}"
    return number if _E164.fullmatch(number) else ""


async def transfer(ctx: JobContext, caller: rtc.RemoteParticipant, number: str, outbound_trunk_id: str) -> str:
    """Transfers the caller to number (+E.164). Returns "refer", "bridge" or "failed"."""
    try:
        response = await asyncio.wait_for(
            ctx.api.sip.transfer_sip_participant(
                api.TransferSIPParticipantRequest(
                    room_name=ctx.room.name,
                    participant_identity=caller.identity,
                    transfer_to=refer_target(number),
                )
            ),
            REFER_TIMEOUT,
        )
        if getattr(response, "status", None) != STS_TRANSFER_FAILED:
            return "refer"
        logger.warning("the carrier reported the transfer as failed")
    except Exception as exc:  # the carrier rejected the REFER, or it timed out
        logger.warning("REFER failed: %s", exc)
    try:
        # Bridge: call the number on the endpoint's outbound trunk and add it to this room.
        await ctx.api.sip.create_sip_participant(
            api.CreateSIPParticipantRequest(
                sip_trunk_id=outbound_trunk_id,
                sip_call_to=number,
                sip_number=caller_from_called(caller.attributes),
                room_name=ctx.room.name,
                participant_identity=f"xfer-{int(time.time())}",
                wait_until_answered=True,
            )
        )
    except Exception as exc:
        logger.error("bridge failed: %s", exc)
        return "failed"
    return "bridge"

Guard against starting a second transfer while one is running, for example when the caller presses the same key twice.

What RelayDock records

The call's timeline in the panel (and in GET /calls/{id}) gets a step for the REFER:

  • call.transferred (Transferred) when the carrier accepted it, with transfer_code, for example 202. The event feed shows Call transferred.
  • call.transfer_failed (Transfer failed) with the carrier's code.

A bridge appears as a separate outbound call in your call list.